Hello everyone!
Now I will show you the control panel of the
PureBilge.
So this is the control panel, HMI, Human Machine
Interface, and this is where you can control
the machine.
So I will explain what are the buttons and
how to go into the menu.
So first, obviously the green button is to
start the machine and the red button here
is to stop it.
And here you have a few, bit more complex
buttons, and I will just talk about the overboard
control, which is here.
You should press it and then you need to enter
the password if you want to start
the overboard discharge sequence.
And this one also is quite important.
If you have an alarm, something going wrong,
it will blink and then you can click on this
one to see which alarm there is and you click
again and you can acknowledge the alarm.
Here on the side you have the arrows, up and
down, and then enter and back buttons that
are here to help you navigate into the menu.
And here are the numbers to enter different
parameter values.
And here is the screen, so it's a quite simple
one, and so if you just go down without entering
the menu you can start to see some values,
pressure, temperatures, speed and here you
can also from the page number 3 you can change
the feed pump speed, so the flow rate you can
adjust it from here.
And here, page number 6, also you have an action,
you can start flushing of
the oil content meter from there.
And then if you want to enter into the menu,
you press back like this, and from here you
can change the parameters amongst other things,
you can make several things, but main one
is to change parameters.
So I will enter the parameters by press enter,
then there are a lot of parameters. If you
want to know all those parameters you can
look into the parameters list manual, it's
all detailed in there.
And now I will just show you the two most
important parameters that you are using frequently
to adjust machine operation.
So that would be 220, you can just type the
number here instead of going down, it's faster.
So 220 is discharge interval.
This one you need to use quite frequently
to adjust to the content of solids in the feed.
So if you have more solids you need to discharge
more frequently.
To remove the solids from the bowl, so for
example
here it is 60 minutes value of the parameter.
And then you can change to for example 20 minutes,
then it's changed and you can go back.
I will put it back to 60, like this.
Then the other one you are using frequently
is 249, it's the temperature setpoint.
So in the same way you can adjust this temperature
point,
if you want to preheat a bit more the bilge
water.
So this is the basic presentation of the menu
and of the control panel here.
I'll see you later in other PureBilge training
videos.